Available in multiple capacity configurations, the product offers flexible solutions tailored to various application scenarios, including peak-valley arbitrage, dynamic capacity expansion, emergency backup power, and solar-storage integration. Through intelligent energy management, it significantly reduces electricity costs while improving renewable energy utilization efficiency.
With proprietary R&D technology and extensive project experience, HiCCES provides safe, reliable, and cost-effective energy storage solutions, empowering commercial and industrial users to achieve energy optimization and sustainable development goals.
No. |
Item |
Unit |
Specifications |
Remarks |
||||
232kWh |
261kWh |
1P416S |
|
|||||
1 |
Cell Specifications |
/ |
LFP 280Ah 3.2V |
LFP 314Ah 3.2V |
LFP 280Ah 3.2V |
LFP 314Ah 3.2V |
|
|
2 |
Nominal Voltage |
V |
832 |
1331.2 |
|
|||
3 |
Rated Capacity |
Ah |
280 |
314 |
280 |
314 |
|
|
4 |
Rated Energy |
kWh |
232.96 |
261.248 |
372.736 |
417.9968 |
|
|
5 |
Max. Continuous Current |
A |
180 |
201 |
180 |
201 |
|
|
6 |
Recommended Voltage Range |
V |
728V~1040V |
1164.8V~1518.4V |
949V~1518.4V |
|
||
7 |
Rated Charge Power |
kW |
0.5CP |
|
||||
8 |
Rated Discharge Power |
kW |
0.5CP |
|
||||
9 |
Cycle Life |
cls |
≥7500cls |
|
||||
10 |
Dimensions |
mm |
1100*1350*2450 |
1500*1350*2500 |
|
|||
11 |
Weight |
kg |
2600±100kg |
2850±100kg |
3820±20kg |
3900±100kg |
|
|
12 |
Operating Temperature Range |
℃ |
-30℃~60℃ |
|
||||
13 |
Storage Temperature Range |
℃ |
-20℃~35℃ |
|
||||
14 |
Insulation Performance |
MΩ |
≥550MΩ(@DC2500V) |
|
||||
15 |
Withstand Voltage Performance |
mA |
≤5mA(@DC4380V) |
|
||||
16 |
Protection Level |
/ |
IP54 |
|
||||
17 |
Temperature Management Method |
/ |
Liquid Cooling, Liquid Heating |
|
||||
18 |
AC Characteristics |
Nominal Voltage |
V |
AC 400V |
AC 690V |
|
||
19 |
Rated Power |
kW |
105 |
125 |
215 |
|
||
20 |
Max. Continuous Power |
kW |
115.5 |
137.5 |
236.5 |
|
||
21 |
Rated Frequency |
Hz |
50Hz/60Hz |
|
||||
22 |
THD of Voltage |
% |
≤3% (linear load) |
|
||||
23 |
AC Output Mode |
/ |
3-phase 4-wire system |
|
||||
24 |
Fire Fighting System |
Fire-fighting Mode |
|
Multi-sensor detection + active suppression |
|
|||
25 |
Extinguishing medium |
|
Perfluoro |
|
||||
26 |
Protection Mode |
|
Pack-level detection and spraying +Cluster-level detection an spraying |
|
||||
27 |
Grounding Resistance |
Electrical Parts-Cabinet |
Ω |
≤0.2Ω |
|
|||
28 |
Cabinet-Ground |
Ω |
≤4Ω |
|
||||
29 |
Other Configurations |
/ |
Lightning Arrester, Dehumidifier, Water Leakage Sensor |